Rhizon and Solu Systems for Soil pore Water Sampling

Soil Water Sampler Types

Soil Water Samplers. Inert samplers can extract small or larger volumes of (pore) water from soils and sediments in a simple, non-destructive and repeatable manner. Different soil water samplers, developed by i) Rhizosphere Research Products, and ii) Sentek can be used to sample water from both unsaturated and saturated soils, and the extract can be used to measure dissolved compounds such as salt / nutrients, dissolved organic carbon, dissolved gases, plant exudates incl. enzymes, or contaminants. 

MicroRhizon and Rhizon Soil Pore Water Samplers

Rhizon Samplers, hold very small diameters and low dead volumes and are easy to handle. Several types of RRP Rhizons for small to medium soil pore water extraction are available:

  1. MicroRhizon Sampler & Accessories for use in Rhizonbox perforated rear panels,
  2. Rhizon Samplers for use in Rhizoboxes and Rhizonboxes (from top/side entry holes), and
  3. Rhizons for soil pore water sampling tasks in disturbed soils or particular well suited for sampling at depth (MacroRhizons).

Rhizon Sampler Accessories (syringes, vacuum vials) are listed below. Read below on characteristics of the Rhizon microfiltration membrane, and details on the sampling procedure. For continuous measurements of soil moisture content in larger diameter boxes, mesocosms, rhizotrons, and in the field, see soil moisture sensors.

Solu Soil Water Sampler Sentek

Sentek SoluSampler, two types of robust, inert ceramic soil water samplers are available for large volume sampling in the field (Table 6). Read more on SoluSamplers. 

Quote - Soil Water Sampling Equip.

MicroRhizon Sampler

MicroRhizon Samplers for use with Rhizonboxes

MicroRhizons are mainly used in RhizonBoxes and Agar tests. They consist of two parts: a porous part (i.e. microfiltration membrane) of 8 mm with an outer diameter of 1 mm, and a PEEK tube (0.6*0.4 mm; 12 cm long) with a silicone connector that fits onto a syringe. The average pore size of the membrane is 0.15 µm, so no filtering of samples is required prior to analysis. The yield of MicroRhizons is up to 2 ml (depending on pore water availability). Because the MicroRhizon tubing is made of PEEK and a special adhesive, it can be steam sterilized. For MicroRhizons, any standard syringe with a "tip" and a wooden retainer can be used for sampling. The MicroRhizons and the syringe tip are connected by a "silicone connector" - i.e. a small piece of silicone tubing. Types for soil pore water sampling in RhizonBox back panels (RRP19.21.81), or with silicone sleeve (RRP19.21.83) for entry from the side of RhizonBoxes (4.5 mm holes) available.

Models/Types MicroRhizons and Accessories OPEN

 

Product #(Image) Length, membrane [mm] Length, tubing [cm] Description 
19.21.81 8 12 MicroRhizon, 8 mm porous, glued on 12 cm PEEK tube, silicone connector for syringe with tip, 10x - STANDARD - use with Rhizonbox 1.5 mm rear panel holes! Buy MicroRhizons online.
19.21.82 8 12 MicroRhizon, 8 mm porous, glued on 12 cm PEEK tube, PEEK guide (1.6 mm OD), silicone connector for syringe with tip, 10x
19.21.83 8 12 MicroRhizon, 8 mm porous, glued on 12 cm PEEK tube, with silicone sleeve, silicone connector for syringe with tip, 10x - use with Rhizonbox 4.5 mm side holes!
19.21.84 - - Accessory - PEEK tubing, 1.6 mm OD, guide tubing to push the MicroRhizon (19.21.81) into agar or other media, 5 cm
19.21.85 - - Accessory - PEEK extension tubing 0.6 x 0.4 mm,  (including silicone connectors), 30 cm
19.21.88 - - Accessory - Syringe PP set [Syringe PP, 5 ml, tip, with wooden retainers 5 cm], 10x
RB-Rhizonbox - - Accessory - RhizonBoxes; Custom size or Online Shop

Rhizon Samplers - SMS, MOM, CSS and Flex, MacroRhizons

Rhizon CSS and Fley Samplers for Rhizonbox studies

Rhizon Samplers are used for (un-)disturbed soils (see types below), and are ideal to be positioned in Rhizoboxes and RhizonBoxes, pot experiments and the field. Rhizonboxes can be equipped with special 4.5 mm openings on the side wall(s) (e.g. at different depth) to insert CSS Rhizon samplers (diameter of 2.5 mm plus silicon sleeve to prevent leakage of water from the RhizonBox). They can be used to collect water from larger zones (length of porous parts: 5 cm or 10 cm) for analysing macro and micro elements, dissolved organic carbon (DOC), exudates and enzymes, and gases such as dissolved O2 or dissolved CO2. Using Rhizons with a 10 cm porous part, maximum yield of water is approximately 4 ml min-1. Rhizon Flex Samplers are particular suitable for sampling when installed in Rhizoboxes and Rhizonboxes during soil filling / set-up. 

Varieties Rhizon Samplers OPEN

In general, four different Rhizon types (SMS, MOM, CSS, Flex) are available in the following varieties (see below for models / product numbers):

  • with a 5 cm or 10 cm porous part (9 cm for MacroRhizons)
  • with a male luer lock - suitable for creating a vacuum with needles + vacuum tubes, or with a female luer lock - suitable for creating a vacuum with syringes 
  • with 0.15 µm or 0.60 µm pore size.
  • with (# + S) and without silicone sleeve.

Ask for silicone sleeve versions (i.e RRP product number # + S) to prevent Rhizonbox leakage from sampler inlet holes in Rhizonboxes (i.e. sleeves sealing the 4.5 mm holes in the side). Alternatively, the gaps around the sampler tube can also be be sealed with Terostat or similar sealant.

Specifications Rhizon Membrane Properties OPEN

The microfiltration membrane of (Micro-)Rhizon samplers is made of a hydrophilic, inert polymer with no ion exchange properties. Once wet, the membrane is only permeable for liquids, not air. Rhizons have very small diameters and low dead volumes and are easy to handle; once installed for one experiment, they can be used many times.

  • Microfiltration membrane with nominal pore sizes of either 0.12 - 0.18 µm (mean pore size 0.15 µm) OR a mean pore size of 0.6 µm
  • Hydrophilic membrane composed of a blend of polyvinylpyrrolidine and polyethersulfone
  • Structure is asymmetric/microporous
  • High performance and a very good anti-fouling behaviour
  • Suitable for filtration outside-in and inside-out
  • pH range: 2-12
  • Temperature range: 1°C to 90°C
  • Pressure range: -300 to +300 kPa
  • Very high resistance against acids, bases, and oil. High resistance to aliphatic alcohols and aliphatic hydrocarbons
  • Not suitable for organic esters, ketones, ethers, halogenated hydrocarbons, aromatic hydrocarbons and polar organic solvents

Store in a dry, normally ventilated place, away from sources of heat, ignition and direct sunlight. Store between 0 and 50°C (32 - 122F). The membranes should not be exposed to freezing.

References Rhizon Soil Water Samplers OPEN

  • Dutta, S., Saar, R., Lavie, Z., Vered, G., Bradbury, H. J., & Antler, G. (2022). A method for a fast and economical in situ collection of pore water in sandy sediments. Frontiers in Marine Science, 9, 968063.
  • Ikoyi, I., & Schmalenberger, A. (2021). Design and Construction of Repacked Soil Columns for Measuring Solute Transport, Plant Growth and Soil Biota. Bio-protocol, 11(2), e3884-e3884.
  • Jäntti, H., Jilbert, T., Aalto, S. L., Simojoki, A., Mangayil, R., Peura, S., & Rissanen, A. J. (2022). The role of organic matter and microbial community controlling nitrate reduction under elevated ferrous iron concentrations in boreal lake sediments. Hydrobiologia, 849(9), 2145-2160.
  • Kumar, N., Noël, V., Planer-Friedrich, B., Besold, J., Lezama-Pacheco, J., Bargar, J. R., ... & Boye, K. (2020). Redox heterogeneities promote thioarsenate formation and release into groundwater from low arsenic sediments. Environmental Science & Technology, 54(6), 3237-3244.
  • Philben, M., Zheng, J., Bill, M., Heikoop, J. M., Perkins, G., Yang, Z., ... & Gu, B. (2019). Stimulation of anaerobic organic matter decomposition by subsurface organic N addition in tundra soils. Soil Biology and Biochemistry, 130, 195-204.
  • Saban, R., Boettcher, M. E., Jenner, A. K., Anthony, S. E., Juransinski, G., von Ahn, C. E., ... & Schmiedinger, I. (2023). Isotope biogeochemistry of the carbon-iron-sulfur cycle in a temperate coastal peatland after flooding by brackish seawater (No. EGU23-16235). Copernicus Meetings.
  • Saban, R., Boettcher, M. E., Jenner, A. K., Anthony, S. E., Juransinski, G., von Ahn, C. E., ... & Schmiedinger, I. (2023). Isotope biogeochemistry of the carbon-iron-sulfur cycle in a temperate coastal peatland after flooding by brackish seawater (No. EGU23-16235). Copernicus Meetings.
  • Tedrow, O. N. R., & Lee, P. F. (2022). Use of Wild Rice (Zizania palustris L.) in Paddy-Scale Bioassays for Assessing Potential Use of Mining-Influenced Water for Irrigation. Mine Water and the Environment, 41(4), 938-953.
  • Van De Meutter, F., Mortelmans, J., & Gyselings, R. (2020). Soil salinity determines the diversity of snail-killing flies (Diptera: Sciomyzidae) in brackish marshes. European Journal of Entomology, 117, 289-294.

Rhizon Sampler Types - Features

Rhizon SMS Sampler

Rhizon SMS. For installation in disturbed soils, lab, greenhouse (pots, columns), and in upper layer in the field. For analysing macro elements, not suitable for analyzing metals and DOC. SS 316 strengthener wire (metal) can be bent permanently. Can be used in Rhizonboxes with restrictions (i.e. wait until soil contact is re-established).

Rhizon MOM Sampler

Rhizon MOM. For installation in disturbed soils etc. as for SMS. For analysing macro and micro elements, dissolved gases and DOC. MOM samplers have a tip with a bulb (2.8 mm) and need several hours or days to achieve a good contact between soil and sampler. Strengthener is a glass fibre wire. Can be used in Rhizonboxes with restrictions (i.e. wait until soil contact is re-established). See Rhizon Sampler Accessories.

Models/Types Rhizon types SMS and MOM OPEN

 

Product number (image link) Length, membrane [cm] Length, tubing [cm] Description of SMS / MOM Rhizon Product (Type / Variation)
19.21.01 10 12 Rhizon, SMS (for macro elements, not suitable for metals & DOC), 0.15 µm pore size, 10 cm porous part, glued on 12 cm PVC/PE tube, samplers have a SS 316 strengthener wire (can be bent permanently), male luer, 10 per set
19.21.01F 10 12 Rhizon, SMS as above (19.21.01) but with female luer, 10x
19.21.05 5 12 Rhizon, SMS (for macro elements, not suitable for metals & DOC), 0.15 µm pore size, 5 cm porous part, glued on 12 cm PVC/PE tube,  samplers have a SS 316 strengthener wire (can be bent permanently), male luer, 10 per set
19.21.05F 5 12 Rhizon, SMS as 19.21.05 but with female luer, 10x
19.60.01F 10 12 Rhizon, SMS (for macro elements, not suitable for metals), 0.6 µm pore size, 10 cm porous part, glued on 12 cm PVC/PE tube, samplers have a SS 316 strengthener wire which can be bent permanently, female luer, 10 per set
19.60.05F 5 12 Rhizon, SMS as 19.60.01F but with a 5 cm porous part, glued on 12 cm PVC/PE tube, samplers have a SS 316 strengthener wire (can be bent permanently), female luer, 10 per set
       
19.21.21 10 12 Rhizon, MOM (for macro & micro elements incl. metals, dissolved gases and DOC), 0.15 µm pore size, 10 cm porous part, glued on 12 cm PVC/PE tube, glass fiber wire as strengthener, tip with bulb (bulb diameter 2.8 mm), male luer, 10 per set
19.21.21F 10 12 Rhizon, MOM as above with female luer, 10x
19.21.22 5 12 Rhizon, MOM (for macro & micro elements incl. metals, dissolved gases and DOC), 0.15 µm pore size, 5 cm porous part, glued on 12 cm PVC/PE tube, glass fiber wire as strengthener, tip with bulb (bulb diameter 2.8 mm), male luer, 10 per set
19.21.22F 5 12 Rhizon, MOM as above with a female luer, 10x
19.60.21F 10 12 Rhizon, MOM (for macro & micro elements incl. metals, dissolved gases and DOC), 0.6 µm pore size, 10 cm porous part, glued on 12 cm PVC/PE tube, glass fiber wire as strengthener, tip with bulb (bulb diameter 2.8 mm), female luer, 10 per set
19.60.22F 5 12 Rhizon, MOM as 19.60.21F (above) but with a 5 cm porous part glued on 12 cm PVC/PE tube, glass fiber wire as strengthener, female luer, 10x
Rhizon CSS Sampler for Rhizonboxes

Rhizon CSS. For direct sampling in cores, undisturbed soils and Rhizonboxes (with silicon sleeves, from side). For analysing macro and micro elements incl. metals, dissolved gases and DOC. CSS samplers have a flat tip (2.5 mm) of the diameter of the porous part. The direct contact between the soil and the porous part makes CSS samplers suitable for immediate sampling - when inserted e.g. through the side holes of Rhizonboxes. Strengthener is a 10-15 cm glass fibre wire. The porous membrane (5 or 10 cm in length) should be fully inserted into the soil and must be at least 0.5 cm away from the outside. 1st choice for Rhizonbox sampling from the side; immediate sampling. 

Rhizon Flex Soil Water Sampler

Rhizon Flex. For disturbed soils or positioned during the filling of Rhizo(n)boxes (from the side holes OR top) or pots. For analysing macro and micro elements similar to CSS. In contrast to CSS, the strengthener is a nylon wire, and the long tube length makes it easy to install them at the intended soil depth and from the top of Rhizoboxes. Good choice for Rhizobox sampling when installed during set-up. See Rhizon Sampler Accessories.

Models/Types Rhizon types CSS and Flex OPEN

 

Product number (Image link) Length, membrane [cm] Length, tubing [cm] Description of CSS / Flex Rhizon Product (Type / Variation)

19.21.23, 

19.21.23S

5 12

Rhizon CSS (for macro & micro elements incl. metals, dissolved gases and DOC in disturbed soils), can be inserted for direct sampling into Rhizonboxes through side holes,  0.15 µm pore size, 5 cm porous part, glued on 10 cm glass fiber wire as strengthener, tip flat, male luer, 10 per set; S = including silicone sleeve

19.21.23F,

19.21.23FS

5 12 Rhizon CSS as above but with female luer, 10 per set, S = incl. silicone sleeve
19.21.24, 19.21.24S 10 12 Rhizon CSS (for macro & micro elements incl. metals, dissolved gases and DOC in disturbed soils), can be inserted into Rhizonboxes through side holes, 0.15 µm por size, 10 cm porous part, glued on 15 cm glass fiber wire as strengthener, tip flat, male luer, 10 per set, S = incl. silicone sleeve
19.21.24F, 19.21.24FS 10 12 Rhizon CSS;as above but with female luer, 10 per set, S = incl. silicone sleeve
19.60.23F, 19.60.23FS 5 12 Rhizon CSS (for macro & micro elements incl. metals, dissolved gases and DOC in disturbed soils), can be inserted into Rhizonboxes through side holes, 0.60 µm pore size, 5 cm porous part, glued on 10 cm glass fiber wire as strengthener, tip flat, female luer, 10 per set, S = incl. silicone sleeve
19.60.24F, 19.60.24FS 10 12 Rhizon CSS as 19.60.23F (above) but with 10 cm porous part, glued on 15 cm glass fiber wire as strengthener, female luer, 10x, S = incl. silicone sleeve
       
19.21.25 10 60 Rhizon Flex (for macro & micro elements incl. metals, dissolved gases and DOC in disturbed soils), have to be positioned during the filling of Rhizoboxes, pots etc., 0.15 µm pore size, 10 cm porous part, glued on 60 cm PVC/PE tube, nylon wire as strengthener, male luer, 10 per set
19.21.25F 10 60 Rhizon Flex as above but with a female luer, 10x
19.21.26 5 30 Rhizon Flex (for macro & micro elements incl. metals, dissolved gases and DOC in disturbed soils), have to be positioned during soil filling, 0.15 µm pore size, 5 cm porous part, glued on 30 cm PVC/PE tube, nylon wire as strengthener, male luer, 10 per set
19.21.26F 5 30 Rhizon Flex as above with female luer, 10 per set
19.60.26F 5 30 Rhizon Flex (for macro & micro elements incl. metals, dissolved gases and DOC in disturbed soils), have to be positioned during soil filling, 0.6 µm pore size, 5 cm porous part, glued on 30 cm PVC/PE tube, nylon wire as strengthener, female luer, 10 per set
19.60.25F 10 60 Rhizon Flex as 19.60.26F but with 10 cm porous part, glued on 60 cm PVC/PE tube, nylon wire as strengthener, female luer, 10x
MacroRhizon

MacroRhizon. For field research & placement at depth. For analysing macro and micro elements incl. metals, dissolved gases and DOC. They have a porous membrane (9 cm) with an outer diameter of 4.5 mm and a pore size of 0.15 µm. MacroRhizons are only available with female luer lock, suitable for creating a vacuum with syringes. Four lengths available are 0 (=direct sampling), 30, 60, and 90 cm tube length. Can also be used in large (i.e. >3 cm deep) Rhizoboxes and Rhizotrons. See below for notes on the installation of MacroRhizons.

Models/Types MacroRhizon Samplers OPEN

Product number (image link) Length, membrane [cm] Length, PVC tubing [cm] Description of MacroRhizon type
19.21.35 9 0 MacroRhizon for installation in the topsoil or horizontal in profile pit walls, 0.15 µm pore size, 9 cm porous part with glass fibre strengthener, no tube = direct connection to female luer, 10 per set
19.21.38 9 30 MacroRhizon for angled installation in subsoil, 0.15 µm pore size, 9 cm porous part with glass fibre strengthener on 30 cm PVC tube. female luer, 10 per set
19.21.39 9 60 MacroRhizon as 19.21.38 but with 60 cm PVC tube, 10 per set
19.21.36 9 90 MacroRhizon as 19.21.38 but with 90 cm PVC tube, 10 per set
19.21.37 9 - MacroRhizon - Spare Membrane (Replacement part)
19.21.51 - - MacroRhizon Insertion Tool, stainless steel pin (4 mm OD, 10 cm long) on 100 cm PVC tube
Soil Auger / corer     Consider a Sentek Soil Auger, or a small diameter VSI Soil Corer (e.g. 48 mm ID) for installation of MacroRhizons at greater soil depth

Rhizon Sampler - Accessories

Rhizon Sampler Accessories - syringes, needles, wooden retainer

What accessories do you need for sampling? This depends on the type of Rhizon ... read more on how to do sampling / soil water manipulation with Rhizons below. All available accessories are listed here. We are happy to suggest required accessories if you describe your use case to us. 

Models/Types Rhizon Accessories OPEN

Rhizon Accessories for soil pore water sampling with the different Rhizon samplers. Essentials for Rhizonbox studies marked in green. (Sampling method: male luer connectors M = needle & vial, OR female luer connectors F = syringe + retainer sampling!).

 

Product number (Image link) Description of Accessory
19.21.02 Needle 40 mm, diameter 0.8 mm, with protecting cap, 10x
19.21.03 Vacuum vials 9 ml, plastic, one-time use, 50x
19.21.04 Syringe set 10 ml female-female, [10 ml syringe + female-female Luer lock connector + wooden retainer 7 cm], 10x
19.21.08F Female-Female luer lock connector (turns a male luer into a female luer), 10x
19.21.08M Male-Male luer lock connector (turns a female luer into a male luer), 10x
19.21.09.7 Wooden retainer 7.0 cm, for syringe 10 ml, 10x
19.21.09.8 Wooden retainer 8.5 cm, for syringe 20 ml, 10x
19.21.09.10 Wooden retainer 10 cm, for syringe 30 ml, 10x
19.21.09.12 Wooden retainer 12 cm, for syringe 50 ml, 10x
19.21.10 Connector/Retainer set, [Luer lock connector 2*female + wooden retainer 7 cm], 10x
19.21.13 Silicone tubing, 1 m,  6 * 2 mm (+ guide wire), slips over and seals tubing outside diameter 2.5-3.2 mm, for about 30 connections
19.21.14 PE Extension tubing, semi rigid, black, 3.2 *1.0 mm, 50 m
19.21.16 PVC/PE extension tubing, flexible, transparent, 2.5 * 1.0 mm, 50 m
19.21.18 Luer lock stopcock 2-way, for sampler flushing without vacuum loss, male-female luer, 10x
19.21.19 Luer lock stopcock 3-way, for sampler flushing and removal of O2, male-female-female luer, 10x
19.21.44 Extension tubing PVC/PE with Luer lock connectors (M, F), 10 x 1 m
19.21.45 Extension tubing PVC/PE with Luer lock connectors (M, F), 10 x 0.5 m  
19.21.88 Syringe set 5 ml, [Syringe 5 ml,  tip, with wooden retainer], 10x - for MicroRhizons
19.21.48 Syringe set 10 ml, [Syringe 10 ml, male luer lock, with wooden retainers 7 cm], 10x
19.21.46 Syringe set 20 ml, [Syringe 20 ml,  male luer lock, with wooden retainers 8.5 cm], 10x
19.21.49 Syringe set 30 ml, [Syringe 30 ml, male luer lock, with wooden retainers 10 cm], 10x
19.21.47 Syringe set 50 ml, [Syringe 50 ml, male luer lock, with wooden retainers 12 cm], 10x
RB-Rhizonbox RhizonBoxes, dedicated rhizonboxes allowing to enter MicroRhizon and CSS Rhizon samplers from a perforated back panel (grid of 1.5 mm holes) / top or side (4.5 mm holes), respectively. Custom-sized Rhizonbox or standard sizes in the online shop
RB-Rhizobox Rhizoboxes, best used with RhizonFlex. See Rhizoboxes - Custom configuration or standard sizes in the online shop
EV-101 EV-101 Evacuator for vacuum vials, to extract soil water with rhizons (male connectors) into (reusable) evacuated glass vials instead of using syringes or one-time exetainers - allowing fast, easy and parallel sampling.

Soil Solution Sampling / Manipulation with MicroRhizons & Rhizons

For sampling rhizosphere pore water, you need a (Micro-)Rhizon sampler and accessories to create a (partial) vacuum (see images below).

  1. MicroRhizon samplers need a syringe with tip and a silicone connector
  2. Rhizon samplers with a female luer lock need a syringe + retainer (OR a male-male luer connector and a vacuum tube)
  3. Rhizon samplers with a male luer lock need a needle and a vacuum tube (evacuated vial), (OR a female-female luer connector and a syringe)
What is the difference? Continue reading

The advantage of vacuum vials is that the sample does not come into contact with air. The advantage of needles/syringes is that the vacuum can be easily restored by pulling back the plunger. However, male-to-male and female-to-female luer connectors are available to easily "correct" your initial choice of sampler luers later. If you use syringes to create a vacuum, wooden retainers can be used to block the plunger -which keeps the vacuum. If you use vacuum vials, you can buy them pre-evacuated or prepare them cost-effectively using the Vacuum Vial Evacuator EV-101. Simply connect a needle to the male Luer lock on Rhizon samplers (or use a female-to-female connector) and insert it through the septa of the vacuum tube.

  

If you cannot extract soil water, you may have forgotten to remove the (blue or red) protective cap from the Rhizon before use. Please check and try again. If the protective cap is already off you may have to wait a little longer. The porous membranes of any (Micro-)Rhizon samplers must be completely wet before you can apply vacuum.

 

If you are interested in testing the response of specific roots or rhizosphere compartments to changes in the soil environment (e.g. salts, heavy metals or other pollutants, dissolved carbon, etc.), you may consider using (micro)rhizons to inject a solution into the soil (next to a specific root or soil region) instead - or use RhizonIrrigators for setting specific irrigation treatments by passive suction or active outflow.

MicroRhizon samplers, syringe with tip, silicone connector
Rhizon samplers with a female luer lock, syringe, retainer
Rhizon samplers with a male luer lock, needle, vacuum tube

Installation of MacroRhizons

MacroRhizons - lettuce field
MacroRhizons - lettuce field

MacroRhizons are only available with a female Luer lock, suitable for creating a vacuum with syringes. It is recommended that the MacroRhizons be installed horizontally in a soil profile wall (direct), or drilled / cored soil hole at an angle of 30 to 45°. This will prevent rainwater from running along the PVC pipe and directly into the membrane.

Want to know more about MicroRhizon installation in the field? Continue reading

An installation tool (19.21.51) is available for placing the MacroRhizons in any hole larger than ~2 cm in diameter and up to ~85 cm deep. Select MacroRhizons of appropriate length (direct, 30, 60, 90 cm). Install in profile wall (direct) or core the soil to the depth where the top end of the 9 cm sampling membrane will be placed, then use the installation tool to create a small (4 mm) hole for insertion of the MacroRhizon membrane section, allowing the sampler to fit tightly in largely undisturbed soil. Backfill the hole above, preferably to approximate the soil profile pattern. Make sure the Luer lock remains clean. For best results, it is recommended to wait 2–3 weeks before sampling; if there is no rain, consider watering the area at the beginning to allow the soil to settle tightly around the sampler. A vacuum for sampling can only be applied when the membrane is wet! You may consider installing MacroRhizons in parallel with Minirhizotron tubes - this will allow you to characterize soil water patterns at different depths along the rooting profile. Drill and Drop soil moisture probes, or access tube-based soil moisture EnviroScan sensors, can provide complementary information on spatial and temporal soil water dynamics.


Sentek Solu Soil Solution Sampler

Sentek SoluSampler for soil water extraction

Sentek SoluSampler, a large soil solution sampler, a lysimeter cup that draws water from the surrounding soil and stores it in an inert ceramic cup for collection and analysis. The large sample cups are ideal for accurate, site-specific analysis of soil water properties such as salinity and nitrate content. Suitable for installation at various depths and field conditions (i.a. high / low flow types for different textured soils). With a rugged and durable design, the SoluSamplers are most suitable for field applications and large sample volumes.

Models/Types Sentek SoluSampler OPEN

SoluSamplers for Soil Water Sampling and Accessories. SoluSamplers are most suitable for field applications and large sample volumes.

 

Product No. Product name Description
ST05500 Solu Low Flow Soil Water Sampler Suitable for most applications, in particular fine textured soil (clay etc ).
ST05505 Solu High Flow Soil Water Sampler Suitable for light textured soils and moist soils (for rapid sampling).
  Solu Accessories Stopcock, syringe (with standard tip) available. Soil corer and other tools for SoluSampler installation can be custom made on demand. 
References Sentek SoluSampler OPEN

  • Phogat, V., Mahadevan, M., Skewes, M., & Cox, J. W. (2012). Modelling soil water and salt dynamics under pulsed and continuous surface drip irrigation of almond and implications of system design. Irrigation Science, 30, 315-333.
  • Skinner, A. (2010). Salt on the Move in Irrigated Agriculture. Irrigation Australia: The Official Journal of Irrigation Australia, 25(4), 10-11.
  • Tapas Kumar Biswas, Gerrit Schrale. (2007). A Tool for Managing Salt & Nutrient Movement in the Root Zone.
  • Williams, C. M. J., Biswas, T. K., Black, I. D., Marton, L., Czako, M., Harris, P. L., ... & Virtue, J. G. (2008). Use of poor quality water to produce high biomass yields of giant reed (Arundo donax L.) on marginal lands for biofuel or pulp/paper. In International Symposium on Underutilized Plants for Food Security, Nutrition, Income and Sustainable Development 806 (pp. 595-602).
Download
SoluSampler for Soil Moisture Extraction Manual v.2.1
Sentek SoluSAMPLER Instruction Manual.V2
Adobe Acrobat Document 827.2 KB
Download
Quote - Soil Water Sampler

Solu Water Sampler - Installation, USe

Solu Sampler installation
SoluSampler Installation

Samples of soil pore water are extracted from the ceramic cup using a large syringe. See the description below and the SoluSampler Manual above (pdf) for more details on installation and operation.

Want to know more about SoluSampler installation and sampling procedure? Continue reading
  1. Select Solu Sampler type: high or low flow according to texture/soil moisture.
  2. Core / drill a hole (c. 40 mm diameter), and to required depth. Keep soil for back-filling.
  3. Wet SoluSamplers. Attach to installation tool for greater depth. 
  4. Insert SoluSampler with tube protruding from the surface (keep stopcock clean).
  5. Prepare a slurry (sieved, sampled soil & water). Preferably use soil from the installation depths soil profile to mix the slurry.
  6. Pour the slurry into the hole to ensure good soil contact, up to 1-2 cm above the SoluSampler. Add some soil, gently tap. Add a 1:1 mixture of sand and betonite to seal the hole and act as a hydraulic barrier.
  7. Fill in the remaining soil to the surface. Allow the Solu Sampler to settle / wet.

Generally, it takes about two weeks after installation for the SoluSampler to provide a representative soil water sample. During this two-week period, discard two or more extracted samples to avoid unrepresentative samples.

 

Sampling:

  1. Vacuum is created using a large syringe (60 ml). Connect the syringe to the stopcock. Create vacuum (potentially using several cycles), close stopcock.
  2. Vacuum is maintained for at least 4 hours. During this time: Soil water is drawn through the ceramic cup and stored in the unit.
  3. After this time, water can be extracted with a (clean) syringe.
  4. After drawing out the soil water, the Sentek SoluSampler should not remain under vacuum conditions until the next time it is used. Consider the long-term effects of bacterial/fungal growth on nutrient analysis; chemical sterilization may be required for extended SoluSampler incubation times but consider effects on soil microbiome, etc. 

Analysis of the collected soil water can be carried out by:

  • Portable Electrical Conductivity (EC) meter (in the field)
  • Nitrate strips (in the field)
  • A wide range of laboratory analysis

Small Rhizotron

Ex situ Root and Soil Observation Systems allow using Rhizon samplers in replicated root and rhizosphere studies, see Rhizoboxes or dedicated Rhizonboxes (for direct insertion of MicroRhizons). 


Dissolved oxygen (DO) cuvette electrode

Measurement of dissolved oxygen or dissolved carbon dioxide in your collected soil water samples. 



Back to Overview - Soil Sampling Tools
  • Soil Sampling
    • Soil Corer
    • Soil Core Storage
    • Soil Ring Sampler
    • Topsoil & Root Corer
    • Soil Water Sampler
    • Root Washer
    • ** Soil Sampling Web Store
  • Soil Moisture Monitoring
  • Root and Soil Functioning
  • Root and Soil Observation Systems
  • Germination Paper-Based Phenotyping & Bioassays
  • Root & Rhizobox Imaging
  • Minirhizotron Systems
  • Shoot Phenotyping & Imaging, Photosynthesis
  • Air Sampling & Gas Flux
  • Insect Rearing & Research
  • Animal Behavior & Physiology
  • Laboratory Instruments
  • Open-hardware
  • Teaching Tools for Biology
  • Distributed Products / Retail

Vienna Scientific Instruments GmbH

Heiligenkreuzer Strasse 466, 2534 Alland, AT

office@vienna-scientific.com

+43 650 69 74 672

Contact VSI on WhatsApp

World Class R%D Partners from Austria
About | Terms | Return Policy | Privacy Policy | Cookie Policy | Sitemap
© 2017-2025 Vienna Scientific Instruments GmbH. All rights reserved. Print this page
Log out | Edit
  • Home
  • Engineering
    • Product Development
    • Prototyping
    • Custom-made Spare Parts
    • Field Technical Services
  • Science
    • Research
      • Cross-Sectoral Collaboration
      • BarleyMicroBreed
      • C-SALS
      • HuLK Humus
      • FutureArctic
      • ISO-Drone
      • NextMR-IAA (ATTRACT)
      • PHENET
      • Conferences & Publications
    • Scientific Services
  • Products
    • Soil Sampling
      • Soil Corer
      • Soil Core Storage
      • Soil Ring Sampler
      • Topsoil & Root Corer
      • Soil Water Sampler
      • Root Washer
      • ** Soil Sampling Web Store
    • Soil Moisture Monitoring
      • Drill & Drop Probe
      • EnviroScan Precission
      • Diviner 2000
    • Root and Soil Functioning
      • Soil Respiration
      • Nitrogen Fixation
    • Root and Soil Observation Systems
      • Rhizoboxes
      • RhizonBoxes
      • Hydroponic RootBoxes
      • Racks & Light Shielding
      • Imaging & Manipulation Stands
      • Rhizobox Respiration Chambers
      • Rhizobox Irrigation
      • Rhizotrons & Root Windows
      • * Rhizobox Configuration Form
      • ** Rhizobox Web Store
    • Germination Paper-Based Phenotyping & Bioassays
      • Root Phenoboxes
      • Growth Pouches
      • Germination Pouches
      • Pouch Phenoracks and Stands
      • * Growth Pouch Configuration Form
      • ** Growth Pouch Web Store
    • Root & Rhizobox Imaging
      • Rhizobox Imaging
      • RhizoPot Scanner
      • Benchtop Root Analyzer
      • 2D Root Scanner
      • Root Scanning Trays
      • ** Root Imaging Web Store
    • Minirhizotron Systems
      • Manual MR Systems
      • Semi-Automatic MR Systems
      • Automatic MR Systems
      • Minirhizotron Tubes
      • Coring System for MR Tubes
      • ** Minirhizotron Web Store
    • Shoot Phenotyping & Imaging, Photosynthesis
      • Phenobox
      • Plant Imaging Chamber
      • Chlorophyll Fluorescence
      • Photosynthesis
    • Air Sampling & Gas Flux
      • Automatic Air Sampler
      • UAV Air Sampler
      • Vial Evacuator
      • HT Gas Flux Autosampler LAB
      • Teflon / PTFE Chambers
      • Ecosystem Respiration Chambers
      • CO2 Analyzers 2000 ppm
      • High CO2 Analyzers 10%
      • O2 Analyzers
      • O2/CO2 Analyzers
      • Methane CH4 Analyzer
      • Hydrogen H2 Analyzer
      • Gas Multichannel, Monitor, Pump
      • Pressure Sensors Regulators
      • Gas Mixing & Control
      • Dissolved CO2 Analyzer
      • Dissolved O2 Sensor
      • Qubit Interfaces and Software
    • Insect Rearing & Research
      • Tray and Rack Larval Systems
      • Larvae Mass Rearing Trays
      • Automated Larval Feeding
      • Rearing / Oviposition Cages
      • Oviposition Brushing Machine
      • Insect Sex Separator
      • Insect Collector
      • Release Cages
      • Insect Chill Plates
      • Insect Respirometry
      • Farming Tray Systems
    • Animal Behavior & Physiology
      • Animal Respirometry
      • Aquatic Respirometry
      • Aquatic Control Systems
      • Harness Housings
      • Ports (Photo interrupter Sensors)
      • Operant Boxes
    • Laboratory Instruments
      • Biobase Catalog
      • Labtare Catalog
    • Open-hardware
    • Teaching Tools for Biology
      • Animal and Plant Biology Hands-on
    • Distributed Products / Retail
  • Quote
    • Quote - Soil Corer + Root Washer
    • Quote - Soil Water Sampling
    • Quote - Growth Pouches
    • Quote - Root Shoot Imaging
    • Quote - Minirhizotron
    • Quote - Air Sampling Vial Evac
    • Quote - Gas Analyzers
    • Quote - Insect Rearing and Research
  • Contact
    • Distributors
    • Contact Form
      • Email - Edaphic Scientific (Australia, New Zealand)
      • Email - Eco-Mind (China)
      • Email - DTPLENVIRO (India)
      • Email - Qubit (North America)
    • Partners & Customers
    • Customer Support
      • FAQs
      • Calibration, Maintenance & Repairs
      • Returns
      • Meet Us
    • Social Media
    • Vacancies
    • About VSI
  • Store
  • News
  • Scroll to top