Hydrogen H2 Gas Analyser

Q-S121 Gas-phase Hydrogen Analyser

Q-S121 Hydrogen H2 Analyzer

Q-S121 H2 Gas Analyser, a flow-through system enabling precise measurements of H2 gas in the range of 0-100 ppm. If your requirements extend beyond this range, customisation options are available. This analyser uses a tin-dioxide (SnO2) semiconductor sensing element, and its output is sensitive to background gas composition (N2 vs Ar) and oxygen levels. The Q-S121 is factory calibrated at 21% O2 for both N2 and Ar background gases. If the Q-C610 LabQuest Mini Data Interface and the optional Q-C901 Logger Pro software are chosen, a corresponding experimental setup file is supplied. This file makes it easy to correct the voltage output to accurately reflect the molecular hydrogen concentration in ppm. The versatility of the Q-S121 extends to applications such as measuring nitrogenase activity, particularly in H2 evolution within the uptake hydrogenase (HUP) minus symbioses of legumes. In particular, this gas-phase hydrogen analyser is an integral part of the Q-NF1LP Nitrogen Fixation Package.

Q-S121 Molecular Hydrogen Analyzer - Features

  • Measurement of low levels of H2 gas (0-100 ppm)
  • Can be customised for higher hydrogen levels
  • Sensitive to background gas and O2 levels
Specifications Q-S121 H2 OPEN

Detection principle: Metal oxide semiconductor with heated alumina ceramic tube, flow-through; output sensitive to O2 concentration and background gas, solvents, water vapour

 

Detection range: 0 to 100 ppm H2 (higher range in customised units)
Output: 0 to 5 V analogue to digital interface
Resolution / Accuracy: ±0.01 ppm / ±0.03 ppm, 0 to 10 ppm range; ±0.02 ppm / ±0.05 ppm, 10 to 40 ppm range; ±1.05 ppm / ±1.00 ppm, 40 to 100 ppm range
Response time (90%): 2 min (high H2 preconditioning required)
Calibration at 21% O2 in N2 and Ar supplied with H2 analyser

Operating Temperature: 0-60°C

Power supply: 12 V DC
Dimensions: 5.5 to 9.5 x 9.5 x 17 cm (H x W x D)
Weight: 1 kg

Get Quote

Contact us for receiving the free manual of the Hydrogen Analyser.



Overview - Hydrogen Gas Analysis

There are several methods for analysing hydrogen (H2) in the gas phase, each with its own advantages and applications. Here are three common methods, along with some references for each (below): ... Show more
  • Infrared Spectroscopy: Infrared spectroscopy analyses, such as employed in the H2 analysers above, measure hydrogen gas by its absorption of infrared radiation, revealing molecular vibrations specific to H2. This non-destructive technique is used for both qualitative and quantitative analysis of hydrogen content in various samples, including biology, crude oil and petrochemical products. Its versatility makes it valuable in industries requiring accurate and instant measurements of hydrogen concentration.
  • Gas Chromatography (GC): Gas chromatography separates hydrogen gas from other components in a sample based on their different affinities for a stationary phase. The elution time allows quantitative analysis of the hydrogen concentration. It is widely used for purity assessment in industrial hydrogen production and ensures accurate characterisation of trace impurities. Gas samples, taken with our automatic whole air sample systems, can subsequently be analysed with gas chromatographs for hydrogen.  
  • Mass Spectrometry (MS): Mass spectrometry identifies and quantifies hydrogen isotopes by measuring the mass-to-charge ratio of ions produced by the sample. This method is highly sensitive and allows precise detection of impurities in hydrogen. Applications range from monitoring purity in hydrogen production to research in fields as diverse as environmental science and materials research.
References Methods Hydrogen Gas Analysis OPEN

  • Constant, P., Poissant, L., & Villemur, R. (2008). Annual hydrogen, carbon monoxide and carbon dioxide concentrations and surface to air exchanges in a rural area (Québec, Canada). Atmospheric Environment, 42(20), 5090-5100.
  • Hargreaves, M. D., & Page, C. S. (2018). "Infrared spectroscopy for hydrogen gas analysis in petrochemicals." Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy, 188, 437-443.
  • Fujii, A., & Mizuse, K. (2013). Infrared spectroscopic studies on hydrogen-bonded water networks in gas phase clusters. International Reviews in Physical Chemistry, 32(2), 266-307.
  • Meredith, L. K., Commane, R., Munger, J. W., Dunn, A., Tang, J., Wofsy, S. C., & Prinn, R. G. (2014). Ecosystem fluxes of hydrogen: A comparison of flux-gradient methods. Atmospheric Measurement Techniques, 7(9), 2787-2805.
  • Speltini, A., Sturini, M., Maraschi, F., Dondi, D., Fisogni, G., Annovazzi, E., ... & Buttafava, A. (2015). Evaluation of UV-A and solar light photocatalytic hydrogen gas evolution from olive mill wastewater. International Journal of Hydrogen Energy, 40(12), 4303-4310.
  • Speltini, A., Sturini, M., Dondi, D., Annovazzi, E., Maraschi, F., Caratto, V., ... & Buttafava, A. (2014). Sunlight-promoted photocatalytic hydrogen gas evolution from water-suspended cellulose: a systematic study. Photochemical & Photobiological Sciences, 13(10), 1410-1419.
  • Tan, Y., & Kagan, M. R. (2016). "Quantitative mass spectrometry for hydrogen and helium analysis." International Journal of Mass Spectrometry, 399-400, 20-27.
  • Vázquez, M., Blanco, C. G., Pino, V., & Anderson, J. L. (2013). "Gas chromatographic determination of hydrogen." Journal of Chromatography A, 1285, 155-160.

Q-NF1LP Nitrogen Fixation Package

The Q-S121 H2 Analyser is a module of the Q-NF1LP Nitrogen Fixation Package, using H2 evolution to non-destructively determine the N fixation by rhizobia.


Hydrogen sampling into vials

For automatic hydrogen / air-mixture sampling into evacuated vials, allowing for later gas chromatographic analysis etc., the AS-100 air sampler has been developed. Air sampler for UAV available.


CO2 Analyzer Models

For measurements of CO2 or O2 in the gas phase, consider the different models of CO2 IRGAs, or O2 gas analyser models.



Back to Overview - Air Sampling Tools & Gas Flux Analyzers
  • Soil Sampling
  • Soil Moisture Monitoring
  • Root and Soil Functioning
  • Root and Soil Observation Systems
  • Germination Paper-Based Phenotyping & Bioassays
  • Root & Rhizobox Imaging
  • Minirhizotron Systems
  • Shoot Phenotyping & Imaging, Photosynthesis
  • Air Sampling & Gas Flux
    • Automatic Air Sampler
    • UAV Air Sampler
    • Vial Evacuator
    • HT Gas Flux Autosampler LAB
    • Teflon / PTFE Chambers
    • Ecosystem Respiration Chambers
    • CO2 Analyzers 2000 ppm
    • High CO2 Analyzers 10%
    • O2 Analyzers
    • O2/CO2 Analyzers
    • Methane CH4 Analyzer
    • Hydrogen H2 Analyzer
    • Gas Multichannel, Monitor, Pump
    • Pressure Sensors Regulators
    • Gas Mixing & Control
    • Dissolved CO2 Analyzer
    • Dissolved O2 Sensor
    • Qubit Interfaces and Software
  • Insect Rearing & Research
  • Animal Behavior & Physiology
  • Laboratory Instruments
  • Open-hardware
  • Teaching Tools for Biology
  • Distributed Products / Retail

Vienna Scientific Instruments GmbH

Heiligenkreuzer Strasse 466, 2534 Alland, AT

office@vienna-scientific.com

+43 650 69 74 672

Contact VSI on WhatsApp

World Class R%D Partners from Austria
About | Terms | Return Policy | Privacy Policy | Cookie Policy | Sitemap
© 2017-2025 Vienna Scientific Instruments GmbH. All rights reserved. Print this page
Log out | Edit
  • Home
  • Engineering
    • Product Development
    • Prototyping
    • Custom-made Spare Parts
    • Field Technical Services
  • Science
    • Research
      • Cross-Sectoral Collaboration
      • BarleyMicroBreed
      • C-SALS
      • HuLK Humus
      • FutureArctic
      • ISO-Drone
      • NextMR-IAA (ATTRACT)
      • PHENET
      • Conferences & Publications
    • Scientific Services
  • Products
    • Soil Sampling
      • Soil Corer
      • Soil Core Storage
      • Soil Ring Sampler
      • Topsoil & Root Corer
      • Soil Water Sampler
      • Root Washer
      • ** Soil Sampling Web Store
    • Soil Moisture Monitoring
      • Drill & Drop Probe
      • EnviroScan Precission
      • Diviner 2000
    • Root and Soil Functioning
      • Soil Respiration
      • Nitrogen Fixation
    • Root and Soil Observation Systems
      • Rhizoboxes
      • RhizonBoxes
      • Hydroponic RootBoxes
      • Racks & Light Shielding
      • Imaging & Manipulation Stands
      • Rhizobox Respiration Chambers
      • Rhizobox Irrigation
      • Rhizotrons & Root Windows
      • * Rhizobox Configuration Form
      • ** Rhizobox Web Store
    • Germination Paper-Based Phenotyping & Bioassays
      • Root Phenoboxes
      • Growth Pouches
      • Germination Pouches
      • Pouch Phenoracks and Stands
      • * Growth Pouch Configuration Form
      • ** Growth Pouch Web Store
    • Root & Rhizobox Imaging
      • Rhizobox Imaging
      • RhizoPot Scanner
      • Benchtop Root Analyzer
      • 2D Root Scanner
      • Root Scanning Trays
      • ** Root Imaging Web Store
    • Minirhizotron Systems
      • Manual MR Systems
      • Semi-Automatic MR Systems
      • Automatic MR Systems
      • Minirhizotron Tubes
      • Coring System for MR Tubes
      • ** Minirhizotron Web Store
    • Shoot Phenotyping & Imaging, Photosynthesis
      • Phenobox
      • Plant Imaging Chamber
      • Chlorophyll Fluorescence
      • Photosynthesis
    • Air Sampling & Gas Flux
      • Automatic Air Sampler
      • UAV Air Sampler
      • Vial Evacuator
      • HT Gas Flux Autosampler LAB
      • Teflon / PTFE Chambers
      • Ecosystem Respiration Chambers
      • CO2 Analyzers 2000 ppm
      • High CO2 Analyzers 10%
      • O2 Analyzers
      • O2/CO2 Analyzers
      • Methane CH4 Analyzer
      • Hydrogen H2 Analyzer
      • Gas Multichannel, Monitor, Pump
      • Pressure Sensors Regulators
      • Gas Mixing & Control
      • Dissolved CO2 Analyzer
      • Dissolved O2 Sensor
      • Qubit Interfaces and Software
    • Insect Rearing & Research
      • Tray and Rack Larval Systems
      • Larvae Mass Rearing Trays
      • Automated Larval Feeding
      • Rearing / Oviposition Cages
      • Oviposition Brushing Machine
      • Insect Sex Separator
      • Insect Collector
      • Release Cages
      • Insect Chill Plates
      • Insect Respirometry
      • Farming Tray Systems
    • Animal Behavior & Physiology
      • Animal Respirometry
      • Aquatic Respirometry
      • Aquatic Control Systems
      • Harness Housings
      • Ports (Photo interrupter Sensors)
      • Operant Boxes
    • Laboratory Instruments
      • Biobase Catalog
      • Labtare Catalog
    • Open-hardware
    • Teaching Tools for Biology
      • Animal and Plant Biology Hands-on
    • Distributed Products / Retail
  • Quote
    • Quote - Soil Corer + Root Washer
    • Quote - Soil Water Sampling
    • Quote - Growth Pouches
    • Quote - Root Shoot Imaging
    • Quote - Minirhizotron
    • Quote - Air Sampling Vial Evac
    • Quote - Gas Analyzers
    • Quote - Insect Rearing and Research
  • Contact
    • Distributors
    • Contact Form
      • Email - Edaphic Scientific (Australia, New Zealand)
      • Email - Eco-Mind (China)
      • Email - DTPLENVIRO (India)
      • Email - Qubit (North America)
    • Partners & Customers
    • Customer Support
      • FAQs
      • Calibration, Maintenance & Repairs
      • Returns
      • Meet Us
    • Social Media
    • Vacancies
    • About VSI
  • Store
  • News
  • Scroll to top