Multichannel / Gas Switching Systems, Flux Monitoring & gas Pumps

We offer Qubits multichannel gas switching systems, gas pumps and flow monitors in various configurations ranging from 4 to 8 channels and 1–3 litres per minute flow rates. Economically priced, yet accurate and versatile, these gas regulation systems are compatible with a wide range of flux and ecosystem respiration chambers. Contact us to configure gas switching and flow control systems to meet your needs. Specifically, our standard portfolio includes: 

  • Open flow multiplexing systems with 4 or 8 channels
  • Open and closed multiplexing flow systems with 4 or 8 channels
  • Gas Pumps, 0-1 or 0-3/4 Litre per minute flow rates
  • Gas Flow Monitor with Pump - Combi Instruments, 1 or 2 Litre per minute
  • Digital Gas Flow Monitor, 0-1 or 0-2 LPM
  • Manual Flow Meter / Rotameter, various ranges

Gas Chamber Switching Systems

Gas Switching System 8 channels, Q-G244-SF

Multichannel Gas Monitoring / Gas Switching Systems (Q-GSS), allowing to measure gas exchange across multiple samples using a single set of gas analysers. The Gas Switching Systems allow monitoring up to 8 different channels when e.g. used with a single Q-Box system, such as the Low Range RP1LP Insect Respirometry Package and the Animal Q-RP2LP High Range Respirometry Package. For packages such as the Q-NF1LP Nitrogen Fixation Package and the Q-Box CO650 Plant CO2 Analysis Package, the GSS allows up to 4 different samples to be tracked. The multiple channel systems allow simultaneous measurement of respiration (O2 and VCO2), nitrogen fixation, photosynthesis and transpiration on multiple channels. Two versions of the GSS are available:

  • standard version designed for open flow measurements (Q-GSS), and a
  • extended version that supports both open flow and stop flow (Q-GSS-SF) measurements.

Open flow system, 4 or 8 channels (Q-GSS)

Open flow GSS system, 4 or 8 channels (Q-GSS)

A 3/4 L min-1 flow gas pump (Q-P651, see below), is utilized. The reference gas is transported through the Q-G261 low-pressure regulator to the flow meters. Each flow meter provides and controls the gas flow manually to its corresponding chamber. The output gas from all chambers is routed to the gas inlets on the gas switcher (two models: Q-G244 - 8 channels / Q-G243 - 4 channels). The software chooses the corresponding chamber, and its gas is sent through a solenoid valve linked to that channel to the analysers and flow monitor. The multiplexing between chambers is managed by the digital control unit (Q-C200) and the software. The other chambers are meanwhile vented to the atmosphere, guaranteeing continuous gas flow throughout all chambers and preventing the build up of high gas concentrations within chambers. Channel 1 serves as a reference channel as part of an Open Flow setup.

Open & Stop-flow system, 4 or 8 channels (Q-GSS-SF)

Open and Stop Flow GSS System, 4 or 8 Channels (Q-GSS-SF)

The Gas Switching System has an enhanced version (Q-GSS-SF) that caters to both Open-Flow and Stop-Flow (SF) measurements. The Stop-Flow setup is a more sensitive configuration, e.g. used to measure small, inactive samples in a closed chamber approach. Each chamber comes equipped with a solenoid assembly (Q-A380) that features two 3-way valves. The valves are used to stop the flow through the chamber, allowing e.g. CO2 to accumulate and O2 to be depleted. When deactivated, the gas is subsequently sent through the attached CO2 IRGA or O2 gas analysers etc. for measurement. The gas switching systems have three operational modes,

Show more ... Q-GSS Operation modes
  • Mode 0 conducts sequential measurements on all channels from 1 to 8 (in an eight-channel system), with the reference channel measured every 8 channels.
  • Mode 1 allows sequential measurements of all channels, with the reference channel measured after each sample channel. This mode guarantees a more frequent reference signal measurement. Users can select the number of channels, mode, dwell time (for each channel), and event time (the time period for calculating average data at the end of each dwell time) using the LoggerPro software.
  • Manual mode can be choosen to observe a single channel (e.g. during experiment setup).

Q-GSS - features

  • Gas Switching Systems with four or eight channels
  • Conduct gas exchange measurements across multiple channels with a single set of analysers
  • The Standard Q-GSS allows for open flow measurements, while the Enhanced Q-GSS-SF offers both open and stop flow measurements
  • Effortlessly control the system to collect data and perform final calculations through the software
  • View summarized data by channel in comprehensive graphs and tables of the software

Optional: 

  • Gas Concentration Control System
Components Gas Switching System /
Chamber Multiplexer
OPEN

Table 1: Components of the multichannel Gas Switching Systems, different configuations (4-8 channels, open flow or open flow + closed chamber mode) and optional, custom made flux chambers available

 

Product No. Description
Q-GSS-4 system Standard Gas Switching System with 4 channels, open flow mode
Q-GSS-8 system Standard GSS with 8 channels, open flow mode
Q-GSS-SF-4 system Extended Gas Switching System with 4 channels, open flow and stop flow mode
Q-GSS-SF-8 system Extended GSS with 8 channels, open flow and stop flow mode
  The GSS systems above contain the following components (depending on model):
Q-G243 Four Channel Gas Switcher, in Q-GSS-4 and Q-GSS-SF-4
Q-G244 Eight Channel Gas Switcher, in Q-GSS-8 and Q-GSS-SF-8
Q-C200 Digital Control Unit
Rotameter Flow Meters (4x or 8x, in 4 or 8 channel systems, respectively)
Q-G261 Low-Pressure Regulator
Q-A380 Solenoid valve, for stop-flow measurements (enhanced GSS-FS only); (4x or 8x, in 4 or 8 channel systems, respectively)
Q-GSS-Tubing Tubing and Connectors
Q-GSS-ExFile Customized Experimental Files (for Logger Pro software)
   
Optional  
Q-C901 LoggerPro Software
Qubit Flow-through chambers Custom chambers
VSI Ecosystem respiration chambers Custom open-flow chambers
GSS Software, raw data per channel
Get Quote

Gas Pumps and Flow Monitors

Gas pumps and flow monitors are crucial components of any gas exchange or control system. Consistency and precision are paramount in gas regulation, and the Qubit products deliver exactly that. The high-precision gas pumps and flow monitors are suitable for both low and high flow applications, as well as custom options for various use cases.

Gas Pumps Q-P103 / Q-P651 - 1 or 3 L min-1

Q-P103 Gas pump 1 L per minute

Q-P103 Gas Pump (0-1 L min-1), which utilizes a diaphragm-style design, can produce gas flows of up to 1 litre per minute. Its tranquil operation is ensured by rubber feet and an internal rubber pump mount. Luer-type gas inlet and outlet openings permit easy hooks up to any gas exchange system. A potentiometer allows precise regulation of pump speed, varying from 50 to 100%, to reduce the chances of unintended adjustments. Additionally, two needle valves located at the rear plate of the unit enable the precise adjustment of the gas flow rate. The internal outlet laminar dampening volume ensures the reduction of pressure pulses, rendering the device suitable for usage with laminar mass flow sensors. Possible applications of this gas pump include supplying gas to gas analysers, delivering gas to algal cultures or aquaculture, .... and serving as an essential component of Q-Box Research Packages.

Q-P651 Diaphragm Gas Pump (3 Liter per minute)

Q-P651 Gas Pump (0-3/4 L min-1), as a diaphragm, oil-less pump, is used to supply gas to gas exchange systems etc. The maximum unrestricted gas flow generated by the Q-P651 pump model is ~3-4 Litres per minute (at ~330 mA).

Gas Pump - Features

Back Panel of Gas pumps with gas and power connectors and two needle valves
  • Maximum flow of 1 or 3-4 L min-1 under no load, depending on model
  • Simple operation
  • Quiet, diaphragm pump
  • Two valves to adjust the inflow and outflow of gas
  • Potentiometer allows accurate control of pump speed
  • Internal outlet laminar dampening volume leads to reduced pressure pulses
Specifications Gas Pumps
Q-P103 and Q-P651
OPEN

Working principle: Oil-less diaphragm pump


Flow control: Two needle valves, speed control potentiometer
Gas ports: Luer-Lock gas in and out 
Pressure, maximum: 12.4 kPa (Q-P103) or 100 kPa (Q-P651)
Vacuum, maximum: 12.5 kPa (Q-P103) or 47.4 kPa (Q-P651)
Gas flow (no load), maximum: 1 Litre per min (Q-P103) or 3-4 L min-1 (Q-P651)
Power supply: 12 V, maximum current draw of 215 mA (Q-P103) or 330 mA (Q-P651)
Dimensions: 5.5 to 9.5 x 9.5 x 17 cm (H x W x D)
Housing: metal
Weight: 900 g

Weight: 1 kg
Get Quote

Gas Flow Monitor & Pump Instruments Q-G267 (1 L MIN-1) and Q-G268 (2 L MIN-1)

 Q-G268 3 Liter per minute Gas Flow Monitor and Pump

Q-G268 Flow Monitor and Pump (2 LPM), seamlessly combining a digital mass flow meter and gas pump in a single instrument. The gas pump supplies gas to the flow monitor, allowing measurement and continuous tracking of flow rates in the range of 0 to 2 L min-1. Gas flow can be manually adjusted using the two needle valves on the rear of the instrument (see image of rear connector panel below). The analogue signal from the flow monitor is transmitted to a data interface, and displayed in the software. The flow monitors are factory calibrated. The software provides a specific calibration to convert voltage readings into flow rates measured in millilitres of gas per minute. Gas flow can be further controlled by manually adjusting the two needle valves on the rear of the instrument (see image below). To effectively monitor gas flow, the Q-G268 must be connected to a data acquisition interface (such as the Q-C610 LabQuest Mini) and compatible software, such as the C901 Logger Pro software or any other data acquisition software that accepts a 0-5 V analogue signal.

Q-G267 Gas Flow Monitor and Gas Pump 1 liter per minute

Q-G267 Flow Monitor and Pump (1 LPM), supplying gas to the flow monitor for measuring and tracking continuous flow rates within the range of 0 to 1 L per minute.

Gas Flow Monitor and Pump - Features

Back of the instruments - gas flow monitors and pumps
  • Simple operation
  • Two valve adjustment of gas flow in and out
  • 1 or 2 L per minute max. flow (no load), depending on model
  • Universal Luer Lock gas connectors
  • Analogue output 0-5 V for flow measurement
  • Flow rate calibrated in software
  • Optional battery package for enhanced mobility 
Specifications Gas Flow Monitor and Pump Q-G267 and Q-G268 OPEN

Operating conditions: Temperature 5-40°C, rH 10-90%, Pressure <172 kPa

Flow rate range: 0-1 L/min or 0-2L/min, no load 

Max pressure: 6.9 kPa

Max vacuum: 12.5 kPa

Power supply: 12V DC, 500 mA

Dimensions: 5.5 to 9.5 x 9.5 x 17 cm (H x W x D)

Housing material: metal

Weight: 1200 g

Get Quote

Gas Flow Monitor 0-1 or 0-2 L min-1

Q-G266 Flow Monitor (1 L min-1)

Q-G266 Flow Monitor (1 L min-1) or Q-G265 Flow Monitor (2 L min-1), two gas flow monitor models ideal for measuring and tracking continuous flow rates in the range of 0 to 1 L/min or 0 to 2 L/min. Gas can be supplied to the unit's stainless steel Luer inlet port from either a pump or pressurised source. Each unit is factory calibrated; specific calibration values are supplied with each unit. Gas flow can be controlled by manual adjustment using a stainless steel needle valve on the rear of the instrument. To monitor gas flow, both models must be used with a data acquisition interface (e.g. Q-C610 LabQuest Mini) and software such as Q-C901 LoggerPro Software or any other data acquisition software that accepts a 0-5 V analogue signal.

Gas Flow Monitor - Features

Gas Flow Monitor - Back Panel Connectors
Flow Monitor - Back Panel Connectors / Valve
  • Easy to use 0-1 LPM or 0-2 LPM gas mass flow monitors, max. flow rate depending on model
  • Factory calibrated
  • Secure Luer gas connectors
  • Manual adjustment of flow using a needle valve 
  • Gas flow recording in software
Specifications Gas Flow Monitor
Q-G266 and Q-G265
OPEN

Flow rate range: 0-1 L/min (Q-G266) or 0-2 L/min (Q-G265)

Operating conditions: Temperature 5-40°C, rH 0-95%, Pressure <172 kPa (<25 PSI)

Power supply: 12V DC, 500 mA

Dimensions: 5.5 to 9.5 x 9.5 x 17 cm (H x W x D)

Weight: 900 g

Housing material: Metal

References Q-G266 and Q-G265 OPEN

  • Červený, J., Šetlík, I., Trtílek, M., & Nedbal, L. (2009). Photobioreactor for cultivation and real‐time, in‐situ measurement of O2 and CO2 exchange rates, growth dynamics, and of chlorophyll fluorescence emission of photoautotrophic microorganisms. Engineering in Life Sciences, 9(3), 247-253.
Get Quote

Manual Gas Flow Meter

Gas Flow Meter, manual

Manual Flow Meter / Rotameter, for monitoring gas flow rates in various ranges at a maximum pressure of 101 kPa (14.7 PSI). These flow meters are precision instruments particularly suitable for metering carrier gases in chromatography, for indicating and controlling gases in manufacturing processes, and for measuring gas flow in systems for respiration and photosynthesis measurements. Flow meters are available in a variety of ranges for flow rates from 2 ml/min up to 10 L/min. Use Q-G262 Blow Off Valves to ensure that changes in the flow rate at one rotameter will not affect the flow rates of others, providing a reliable and independent control mechanism. For precise control and digital recording of gas flow rates, please see Digital Mass Flow Monitors.

Flow Meter - Features

  • Various flow ranges available
  • Economical
  • Easy to use 
  • Accurate manual measurement and control of gas flow
Types/Models Rotameter,
per Flow Rate
OPEN

Product No. Flow rate
Q-F10 1-10 ml min-1
Q-F50 10-50 ml min-1
Q-F100 20-100 ml min-1
Q-F250 25-250 ml min-1
Q-F500 50-500 ml min-1
Q-F1000 100-1000 ml min-1
Q-F4000 200-4000 ml min-1
Q-F10000 2.5-10 L min-1
Specifications Manual Flow Meter OPEN

Various flow ranges: 2 ml min-1 to 10 L min-1, depending on model

Operating Conditions: Temp. <121°C (<250F), Pressure <1.37 MPa (<200 PSIG)

Dimensions: 14.0 x 2.5 x 3.2 cm (H x W x L), base: 7.6 x 7.6 cm (W x L)

Weight: 350 g

Materials: Metal (black), glass, clear colourless plastic

Get Quote

Gas pressure regulators

See the Q-S181 for Air Pressure Measurements and Q-G261 / Q-G262 for Gas Pressure Regulation.


O2 Analysers

If O2 in the gas phase is of interest for your experimentation, see the available O2 gas analyser models.


Carbon dioxide analyzer models

For measurements of CO2 in the gas phase, consider the different CO2 IRGA models; various other gas measurement systems available.



Back to Overview - Gas Sampling & Gas Analysers
  • Soil Sampling
  • Soil Moisture Monitoring
  • Root and Soil Functioning
  • Root and Soil Observation Systems
  • Germination Paper-Based Phenotyping & Bioassays
  • Root & Rhizobox Imaging
  • Minirhizotron Systems
  • Shoot Phenotyping & Imaging, Photosynthesis
  • Air Sampling & Gas Flux
    • Automatic Air Sampler
    • UAV Air Sampler
    • Vial Evacuator
    • HT Gas Flux Autosampler LAB
    • Teflon / PTFE Chambers
    • Ecosystem Respiration Chambers
    • CO2 Analyzers 2000 ppm
    • High CO2 Analyzers 10%
    • O2 Analyzers
    • O2/CO2 Analyzers
    • Methane CH4 Analyzer
    • Hydrogen H2 Analyzer
    • Gas Multichannel, Monitor, Pump
    • Pressure Sensors Regulators
    • Gas Mixing & Control
    • Dissolved CO2 Analyzer
    • Dissolved O2 Sensor
    • Qubit Interfaces and Software
  • Insect Rearing & Research
  • Animal Behavior & Physiology
  • Laboratory Instruments
  • Open-hardware
  • Teaching Tools for Biology
  • Distributed Products / Retail

Vienna Scientific Instruments GmbH

Heiligenkreuzer Strasse 466, 2534 Alland, AT

office@vienna-scientific.com

+43 650 69 74 672

Contact VSI on WhatsApp

World Class R%D Partners from Austria
About | Terms | Return Policy | Privacy Policy | Cookie Policy | Sitemap
© 2017-2025 Vienna Scientific Instruments GmbH. All rights reserved. Print this page
Log out | Edit
  • Home
  • Engineering
    • Product Development
    • Prototyping
    • Custom-made Spare Parts
    • Field Technical Services
  • Science
    • Research
      • Cross-Sectoral Collaboration
      • BarleyMicroBreed
      • C-SALS
      • HuLK Humus
      • FutureArctic
      • ISO-Drone
      • NextMR-IAA (ATTRACT)
      • PHENET
      • Conferences & Publications
    • Scientific Services
  • Products
    • Soil Sampling
      • Soil Corer
      • Soil Core Storage
      • Soil Ring Sampler
      • Topsoil & Root Corer
      • Soil Water Sampler
      • Root Washer
      • ** Soil Sampling Web Store
    • Soil Moisture Monitoring
      • Drill & Drop Probe
      • EnviroScan Precission
      • Diviner 2000
    • Root and Soil Functioning
      • Soil Respiration
      • Nitrogen Fixation
    • Root and Soil Observation Systems
      • Rhizoboxes
      • RhizonBoxes
      • Hydroponic RootBoxes
      • Racks & Light Shielding
      • Imaging & Manipulation Stands
      • Rhizobox Respiration Chambers
      • Rhizobox Irrigation
      • Rhizotrons & Root Windows
      • * Rhizobox Configuration Form
      • ** Rhizobox Web Store
    • Germination Paper-Based Phenotyping & Bioassays
      • Root Phenoboxes
      • Growth Pouches
      • Germination Pouches
      • Pouch Phenoracks and Stands
      • * Growth Pouch Configuration Form
      • ** Growth Pouch Web Store
    • Root & Rhizobox Imaging
      • Rhizobox Imaging
      • RhizoPot Scanner
      • Benchtop Root Analyzer
      • 2D Root Scanner
      • Root Scanning Trays
      • ** Root Imaging Web Store
    • Minirhizotron Systems
      • Manual MR Systems
      • Semi-Automatic MR Systems
      • Automatic MR Systems
      • Minirhizotron Tubes
      • Coring System for MR Tubes
      • ** Minirhizotron Web Store
    • Shoot Phenotyping & Imaging, Photosynthesis
      • Phenobox
      • Plant Imaging Chamber
      • Chlorophyll Fluorescence
      • Photosynthesis
    • Air Sampling & Gas Flux
      • Automatic Air Sampler
      • UAV Air Sampler
      • Vial Evacuator
      • HT Gas Flux Autosampler LAB
      • Teflon / PTFE Chambers
      • Ecosystem Respiration Chambers
      • CO2 Analyzers 2000 ppm
      • High CO2 Analyzers 10%
      • O2 Analyzers
      • O2/CO2 Analyzers
      • Methane CH4 Analyzer
      • Hydrogen H2 Analyzer
      • Gas Multichannel, Monitor, Pump
      • Pressure Sensors Regulators
      • Gas Mixing & Control
      • Dissolved CO2 Analyzer
      • Dissolved O2 Sensor
      • Qubit Interfaces and Software
    • Insect Rearing & Research
      • Tray and Rack Larval Systems
      • Larvae Mass Rearing Trays
      • Automated Larval Feeding
      • Rearing / Oviposition Cages
      • Oviposition Brushing Machine
      • Insect Sex Separator
      • Insect Collector
      • Release Cages
      • Insect Chill Plates
      • Insect Respirometry
      • Farming Tray Systems
    • Animal Behavior & Physiology
      • Animal Respirometry
      • Aquatic Respirometry
      • Aquatic Control Systems
      • Harness Housings
      • Ports (Photo interrupter Sensors)
      • Operant Boxes
    • Laboratory Instruments
      • Biobase Catalog
      • Labtare Catalog
    • Open-hardware
    • Teaching Tools for Biology
      • Animal and Plant Biology Hands-on
    • Distributed Products / Retail
  • Quote
    • Quote - Soil Corer + Root Washer
    • Quote - Soil Water Sampling
    • Quote - Growth Pouches
    • Quote - Root Shoot Imaging
    • Quote - Minirhizotron
    • Quote - Air Sampling Vial Evac
    • Quote - Gas Analyzers
    • Quote - Insect Rearing and Research
  • Contact
    • Distributors
    • Contact Form
      • Email - Edaphic Scientific (Australia, New Zealand)
      • Email - Eco-Mind (China)
      • Email - DTPLENVIRO (India)
      • Email - Qubit (North America)
    • Partners & Customers
    • Customer Support
      • FAQs
      • Calibration, Maintenance & Repairs
      • Returns
      • Meet Us
    • Social Media
    • Vacancies
    • About VSI
  • Store
  • News
  • Scroll to top