Dissolved CO2 (DCO2) Analysis Systems

Dissolved CO2 (DCO2) System, standard
Q-DCO2-ST

Dissolved CO2 Systems (Q-DCO2). Dissolved CO2 (DCO2) Systems measure dissolved pCO2 in water under atmospheric pressure conditions. Systems consist of a DCO2 sampler along with accessories, a non-dispersive infrared CO2 analyser with built-in gas pump, a data interface, and accompanying software. The Rapid Response DCO2-RR System, an extension of the system, features in addition a flow-through Rapid Response Dissolved CO2 sampling system, and a liquid pump.

DCO2 System, Standard Configuration

DCO2 Sampler
DCO2 Sampler Q-S350, PTFE membrane

The pivotal component in the standard system (Q-DCO2-ST) is the DCO2 sampler Q-S350, responsible for sampling pCO2 from the liquid and transporting it to the IRGA. Encased in a PTFE (polytetrafluoroethylene) membrane, the DCO2 sampler can be submerged in water up to ~60 cm (2 feet). The dissolved CO2 in water diffuses through the PTFE membrane into the sampler, where it is conveyed to the CO2 analyser through a closed-loop fixed volume gas stream for detection. Successful operation of the system requires liquid flow past the sampler, and stirring is essential for optimal performance. The PTFE membrane is permeable to gases, but impermeable to water at atmospheric pressure. This system specifically detects the dissolved partial pressure of CO2 in water and is insensitive to carbonates (see figure below). It's important to note that this method of determining CO2 partial pressure does not rely on pH measurements. DCO2 systems can be adapted to a range of CO2 concentrations from ppm to 100% in the gas phase. The standard DCO2-ST system has a response time of 4–10 minutes due to the diffusion process across the PTFE membrane. The speed of response is dependent on the flow of liquid past the DCO2 sampler, emphasising the need to stir the solution thoroughly. Applications include ocean acidification studies, fermentation studies, algae cultivation and other bioreactors, aquaculture, environmental monitoring, waste water management, food and beverage industry, etc. 

Rapid Response Dissolved CO2 System

Q-S400 Rapid DCO2 Sampler, Q-PL175 Liquid Pump
Q-DCO2-RR components: Q-S400 Flow-through Sampler, Q-PL175 Water Pump

Alternatively, a Rapid Response System (Q-DCO2-RR) with a flow-through design is available. This variant employs the DCO2 sampling system, where water circulates through silicone tubes, and gas passes on the opposite side of the tubules in the reverse direction. CO2 gas then diffuses across the tubes from water to the gas stream, ultimately reaching the CO2 sensor for precise measurements. In contrast to the standard DCO2-ST system (described above), the Rapid DCO2-RR flow-through system has a different sampler (Q-S400) and a water pump (Q-PL175), and thus in sum a fast response time of 2–4 minutes. This extends the applications mentioned above to e.g. aquatic animal respirometry.

Q-DCO2 Systems - Features

  • Measurement of dissolved CO2 in fresh and seawater
  • Customised to the required pCO2 range (ppm to 10%)
  • Based on CO2 diffusion from water/solution and infrared gas analysis, NOT based on pH measurements
  • Insensitive to carbonates

Options

  • Rapid Response DCO2-RR System, response time 2-4 min (optional)
  • Logging of additional sensors (pH, O2, etc.)
  • Custom extension of pCO2 range (10-100%)
Components Standard Q-DCO2-ST System OPEN

Product No. Description
Q-DCO2-ST Standard Dissolved CO2 Measurement System, response time 4-10min, 0-2000 ppm
Q-S157-P CO2 Analyzer, 0-2000 ppm range, with pump
Q-S350 DCO2 Sampler
Q-F100 Rotameter / Manual Flow Meter 20-100 ml min-1, to adjust gas flow through the system
Q-S132 Temperature sensor
Q-DCO2-Diff Diffusors, 2x, to set up calibration water baths
Q-C610 LabQuest Mini, data interface
Q-C901 LoggerPro Software
Q-C404 Customized Experimental Setup Files for collection, display and analysis of data
Q-DCO2-Kit Accessories (tubing, Nafion RH equilibrator, PTFE filter, connectors, PTFE sleeve)
Q-DCO2-Manual Manual
   
Options  
Q-S158-P CO2 Analyzer, 0-10% range, with pump - extended range (replaces Q-S157-P)
Other Sensors Optional sensors such as pH, salinity, dissolved O2 can also be included in the DCO2 System for monitoring of other parameters that may be complementary to dissolved CO2.
Q-DCO2-Case Rugged case, for storage and transport
Respiration Chambers Custom made Respiration Chambers
Components Rapid Response Q-DCO2-RR OPEN

Product No. Description
Q-DCO2-RR Rapid Response Dissolved CO2 System, response time 2-4 min, 0-2000 ppm range, with the following components included:
Q-S157-P CO2 Analyzer, 0-2000 ppm range, with pump
Q-S400 DCO2 Sampler
Q-F100 Rotameter / Manual Flow Meter 20-100 ml min-1, to adjust gas flow through the system
Q-PL175 Liquid Pump, 1 L min-1
Q-S132 Temperature sensor
Q-DCO2-Diff Diffusors, 2x, to set up calibration water baths
Q-C610 LabQuest Mini, data interface
Q-C901 LoggerPro Software
Q-C404 Customized Experimental Setup Files, for collection, display and analysis of data
Q-DCO2-Kit Q-DCO2 Accessory Kit (tubing, Nafion RH equilibrator, PTFE filter, connectors, PTFE sleeve)
Q-DCO2-Manual Manual
   
Options  
Q-S158-P CO2 Analyzer, 0-10% range, with pump - extended range (replaces Q-S157-P)
Other Sensors Optional sensors such as pH, salinity, dissolved O2 can also be included in the DCO2 System, for monitoring parameters complementary to dissolved CO2
Q-DCO2-Case Rugged case, for storage and transport
Respiration Chambers Custom made Respiration Chambers
References Q-DCO2 Systems OPEN

  • Jio, D. A. (2022). An Examination of the Seawater Aquarium System at Scripps Institution of Oceanography. University of California, San Diego.
  • Ran, L., Lu, X. X., & Liu, S. (2017). Dynamics of riverine CO2 in the Yangtze River fluvial network and their implications for carbon evasion. Biogeosciences, 14(8), 2183-2198.
DCO2 Data in Software Q-C901
DCO2 Data, sample data fish respiration
Get Quote

Overview - Measuring dissolved carbon dioxide

Dissolved CO2 Cycle
Measuring dissolved carbon dioxide (CO2) in water is crucial for many applications such as to understanding the (oceanic) carbon cycle, changes in water acidification and its impact on aquatic ecosystems etc. Several methods are used to assess dissolved CO2 levels, each with its own strengths and applications. For example: Continue reading
  • Colorimetric methods: Colorimetric methods involve the reaction of dissolved CO2 with specific reagents, resulting in a colour change that can be quantified spectrophotometrically. Indicators such as bromothymol blue or phenolphthalein can be used to estimate CO2 concentrations from colour changes.
  • Gas chromatography: Gas chromatography is a highly accurate and sensitive method for measuring dissolved gases, including CO2. The water sample is equilibrated with a gas-phase, and the resulting gas is then injected into a chromatograph for separation and detection.
  • Infrared Gas Analysis (IRGA): IRGA is a non-dispersive infrared technique used to measure the concentration of dissolved gases. In this method, as applied in the Q-DCO2 system described above, the water sample is equilibrated with a gas-permeable membrane and the infrared absorption of CO2 is quantified with a Co2 analyser.
  • Titration methods: In titration methods, a titrant is added to the water sample to neutralise dissolved CO2. The amount of titrant consumed is then used to calculate the concentration of CO2. This method is versatile and can be adapted to different sample types.
  • Membrane Injection Mass Spectrometry (MIMS): MIMS provides real-time, continuous monitoring of dissolved gases, including CO2. The water sample is equilibrated with a membrane and the released gases are directly injected into a mass spectrometer for analysis.
  • Fluorescence sensors: Fluorescence sensors use specific dyes or indicators that react with CO2, causing changes in fluorescence intensity. The level of fluorescence can be correlated to the concentration of dissolved CO2.
  • pH electrodes: Although primarily used to measure pH, pH electrodes indirectly provide information on dissolved CO2 levels. Changes in pH are often associated with the presence of CO2, allowing its concentration to be estimated. See also the Q-ACS Water Control Systems. 
  • Ion Selective Electrodes (ISE): Ion-selective electrodes, such as those designed for carbonate or bicarbonate ions, can be used to estimate dissolved CO2 concentrations. These electrodes selectively measure ions associated with CO2 equilibrium reactions.

These methods provide a range of options for researchers and environmental monitoring agencies to accurately measure dissolved CO2 concentrations in water samples, contributing to a comprehensive understanding of carbon dynamics in aquatic environments.

References Methods for Dissolved CO2 Measurements OPEN

  • Capperucci, R. M., & Rieley, G. (1984). "A fluorescence technique for measurement of concentrations of carbon dioxide and methane in anaerobic ecosystems." Applied and Environmental Microbiology, 48(4), 863-865.
  • Del Giorgio, P. A., & Peters, R. H. (1993). "Balance between respiration and photosynthesis in the determination of planktonic community respiration." Canadian Journal of Fisheries and Aquatic Sciences, 50(11), 282-289.
  • Grasshoff, K., Kremling, K., & Ehrhardt, M. (1983). "Methods of Seawater Analysis." Verlag Chemie.
  • Kankaala, P., & Taipale, S. J. (2004). "Analyzing gas chromatography profiles of aquatic dissolved gases." Journal of Chromatography A, 1023(1), 83-91.
  • Millero, F. J., & Schreiber, J. (1982). "Use of alkalinity to predict calcium carbonate saturation in the ocean." Limnology and Oceanography, 27(4), 782-784.
  • Parsons, T. R., Maita, Y., & Lalli, C. M. (1984). "A Manual of Chemical and Biological Methods for Seawater Analysis." Pergamon Press.
  • Severin, T., Wehrli, B., & Zehnder, A. J. (1992). "Simultaneous measurement of oxygen and carbon dioxide in freshwater sediments by microelectrodes." Limnology and Oceanography, 37(5), 1128-1133.
  • Smith, J. H., & Spencer, D. W. (1954). "Carbon dioxide and the pH of natural waters." Limnology and Oceanography, 1(1), 1-13.

Water Properties Control System

For long-term monitoring and regulation of DCO2 in water tanks., the Aquatic Control System Q-ACS is available.


Fish Respirometry

The Q-AQUA Aquatic Respirometry Package is designed for measurements of Dissolved Oxygen inside an aquatic respirometry chamber - see also for an overview of DCO2 methods.


Dissolved O2 Electrodes on Magnetic Stirrer

Dissolved O2 can be measured with either polarographic electrodes in the Q-OX1LP package, or with the optical DO Sensor Q-S122.


CO2 Analyzer Models

For measurements of CO2 in the gas phase, consider the different CO2 IRGA 0-2000 ppm models (or 0-10% CO2 range). For both CO2 and O2, consider the Q-S159 CO2 and O2 analyser.



Back to Overview - Air Sampling & Gas Analyzers
  • Soil Sampling
  • Soil Moisture Monitoring
  • Root and Soil Functioning
  • Root and Soil Observation Systems
  • Germination Paper-Based Phenotyping & Bioassays
  • Root & Rhizobox Imaging
  • Minirhizotron Systems
  • Shoot Phenotyping & Imaging, Photosynthesis
  • Air Sampling & Gas Flux
    • Automatic Air Sampler
    • UAV Air Sampler
    • Vial Evacuator
    • HT Gas Flux Autosampler LAB
    • Teflon / PTFE Chambers
    • Ecosystem Respiration Chambers
    • CO2 Analyzers 2000 ppm
    • High CO2 Analyzers 10%
    • O2 Analyzers
    • O2/CO2 Analyzers
    • Methane CH4 Analyzer
    • Hydrogen H2 Analyzer
    • Gas Multichannel, Monitor, Pump
    • Pressure Sensors Regulators
    • Gas Mixing & Control
    • Dissolved CO2 Analyzer
    • Dissolved O2 Sensor
    • Qubit Interfaces and Software
  • Insect Rearing & Research
  • Animal Behavior & Physiology
  • Laboratory Instruments
  • Open-hardware
  • Teaching Tools for Biology
  • Distributed Products / Retail

Vienna Scientific Instruments GmbH

Heiligenkreuzer Strasse 466, 2534 Alland, AT

office@vienna-scientific.com

+43 650 69 74 672

Contact VSI on WhatsApp

World Class R%D Partners from Austria
About | Terms | Return Policy | Privacy Policy | Cookie Policy | Sitemap
© 2017-2025 Vienna Scientific Instruments GmbH. All rights reserved. Print this page
Log out | Edit
  • Home
  • Engineering
    • Product Development
    • Prototyping
    • Custom-made Spare Parts
    • Field Technical Services
  • Science
    • Research
      • Cross-Sectoral Collaboration
      • BarleyMicroBreed
      • C-SALS
      • HuLK Humus
      • FutureArctic
      • ISO-Drone
      • NextMR-IAA (ATTRACT)
      • PHENET
      • Conferences & Publications
    • Scientific Services
  • Products
    • Soil Sampling
      • Soil Corer
      • Soil Core Storage
      • Soil Ring Sampler
      • Topsoil & Root Corer
      • Soil Water Sampler
      • Root Washer
      • ** Soil Sampling Web Store
    • Soil Moisture Monitoring
      • Drill & Drop Probe
      • EnviroScan Precission
      • Diviner 2000
    • Root and Soil Functioning
      • Soil Respiration
      • Nitrogen Fixation
    • Root and Soil Observation Systems
      • Rhizoboxes
      • RhizonBoxes
      • Hydroponic RootBoxes
      • Racks & Light Shielding
      • Imaging & Manipulation Stands
      • Rhizobox Respiration Chambers
      • Rhizobox Irrigation
      • Rhizotrons & Root Windows
      • * Rhizobox Configuration Form
      • ** Rhizobox Web Store
    • Germination Paper-Based Phenotyping & Bioassays
      • Root Phenoboxes
      • Growth Pouches
      • Germination Pouches
      • Pouch Phenoracks and Stands
      • * Growth Pouch Configuration Form
      • ** Growth Pouch Web Store
    • Root & Rhizobox Imaging
      • Rhizobox Imaging
      • RhizoPot Scanner
      • Benchtop Root Analyzer
      • 2D Root Scanner
      • Root Scanning Trays
      • ** Root Imaging Web Store
    • Minirhizotron Systems
      • Manual MR Systems
      • Semi-Automatic MR Systems
      • Automatic MR Systems
      • Minirhizotron Tubes
      • Coring System for MR Tubes
      • ** Minirhizotron Web Store
    • Shoot Phenotyping & Imaging, Photosynthesis
      • Phenobox
      • Plant Imaging Chamber
      • Chlorophyll Fluorescence
      • Photosynthesis
    • Air Sampling & Gas Flux
      • Automatic Air Sampler
      • UAV Air Sampler
      • Vial Evacuator
      • HT Gas Flux Autosampler LAB
      • Teflon / PTFE Chambers
      • Ecosystem Respiration Chambers
      • CO2 Analyzers 2000 ppm
      • High CO2 Analyzers 10%
      • O2 Analyzers
      • O2/CO2 Analyzers
      • Methane CH4 Analyzer
      • Hydrogen H2 Analyzer
      • Gas Multichannel, Monitor, Pump
      • Pressure Sensors Regulators
      • Gas Mixing & Control
      • Dissolved CO2 Analyzer
      • Dissolved O2 Sensor
      • Qubit Interfaces and Software
    • Insect Rearing & Research
      • Tray and Rack Larval Systems
      • Larvae Mass Rearing Trays
      • Automated Larval Feeding
      • Rearing / Oviposition Cages
      • Oviposition Brushing Machine
      • Insect Sex Separator
      • Insect Collector
      • Release Cages
      • Insect Chill Plates
      • Insect Respirometry
      • Farming Tray Systems
    • Animal Behavior & Physiology
      • Animal Respirometry
      • Aquatic Respirometry
      • Aquatic Control Systems
      • Harness Housings
      • Ports (Photo interrupter Sensors)
      • Operant Boxes
    • Laboratory Instruments
      • Biobase Catalog
      • Labtare Catalog
    • Open-hardware
    • Teaching Tools for Biology
      • Animal and Plant Biology Hands-on
    • Distributed Products / Retail
  • Quote
    • Quote - Soil Corer + Root Washer
    • Quote - Soil Water Sampling
    • Quote - Growth Pouches
    • Quote - Root Shoot Imaging
    • Quote - Minirhizotron
    • Quote - Air Sampling Vial Evac
    • Quote - Gas Analyzers
    • Quote - Insect Rearing and Research
  • Contact
    • Distributors
    • Contact Form
      • Email - Edaphic Scientific (Australia, New Zealand)
      • Email - Eco-Mind (China)
      • Email - DTPLENVIRO (India)
      • Email - Qubit (North America)
    • Partners & Customers
    • Customer Support
      • FAQs
      • Calibration, Maintenance & Repairs
      • Returns
      • Meet Us
    • Social Media
    • Vacancies
    • About VSI
  • Store
  • News
  • Scroll to top