PTFE-Chambers - Measurement of Volatiles and Reactive Gases

Examples of chamber configurations (c) Timkovsky et al. (2014)
Examples of chamber configurations (c) Timkovsky et al. (2014)

PTFE Gas & Volatile Flux Chambers. Experimentation on highly reactive molecules in the atmosphere requires specific chambers. Teflon chambers (PTFE Chambers) are often used for studies on volatiles and reactive gases because they are relatively chemically inert. PTFE-reaction chambers are thus ubiquitous in studies of atmospheric chemistry.

Teflon Chambers for Experimentation on Reactive Gases and Volatiles

PTFE Reactive Gases Chamber for Plant Studies

TC-400 Teflon Flux Chamber, to study interactions between Ozone, BVOC emissions and plant physiological status. The chamber was developed for the project UOZONE of the University of Natural Resources and Life Sciences, Vienna (BOKU). In brief, all mounting and side parts in contact with the air inside the 40 l plant chamber / reaction chamber are made from Teflon (PTFE). Plants are housed in PET bags. While potential interaction between vapour and PTFE-chamber walls can lead to the underestimation of some compounds, particular for least volatile compounds, the extent of prior use has been reported not to affect the sorption behaviour of Teflon (Zhang et al. 2015) - making the use of Teflon respiration chambers the preferred choice.

PTFE-Chamber - Specification

The TC-400 chamber design is freely configurable to meet the needs of your planned experiments, in particular to meet your target plant size (crown volume) and measured compounds. For example, we can adjust at your request:

  • diameter of the reaction chambers` PTFE bottom (standard: 400 mm), size / location of the plant insertion point (Teflon-coated rubber), and numbers of air outlets realized in the bottom plate,
  • height of air inlet in chamber (standard: 500 mm), and location of air entry point(s) (standard: on top, with diffusor),
  • height of the table (fixed height or adjustable), on wheels or legs, no table etc.

In general, an "inversed design", targeting e.g. BVOC emissions by roots and microbiomes, is conceivable. We are happy to discuss your bespoke Teflon chamber configuration needs in person - adapting it to successfully measure the reactive molecules of your choice. If required, we can source valves, mass flow controllers, activated C filters, and tubing etc. for your experimental set-up.

References TC-400 PTFE Chamber OPEN

  • Fitzky, A. C., Peron, A., Kaser, L., Karl, T., Graus, M., Tholen, D., ... & Rewald, B. 2021. Diversity and interrelations among the constitutive VOC emission blends of four broad-leaved tree species at seedling stage. Frontiers in plant science, 12, 708711.
  • Fitzky, A. C., Kaser, L., Peron, A., Karl, T., Graus, M., Tholen, D., ... & Sandén, H. 2023. Same, same, but different: Drought and salinity affect BVOC emission rate and alter blend composition of urban trees. Urban Forestry & Urban Greening, 80, 127842. 
  • Peron, A., Kaser, L., Fitzky, A.C., Graus, M., Halbwirth, H., Greiner, J. et al. 2020. Combined effects of ozone and drought stress on the emission of biogenic volatile organic compounds from Quercus robur L. Biogeosciences, 2020, 1-27. DOI: 10.5194/bg-2020-260
VSI - PTFE chamber for gas flux measurements
VSI - PTFE chamber for gas flux measurements
VSI - PTFE chamber for gas flux measurements, with oaks
Insertion tables for plant canopy gas flux measurements, side view
PTFE chamber for gas flux measurements, connectors at bottom & openign mechanism
Detail Teflon "disc" for chamber bottom, with gas inlets, outlets and center insertion for tree stem
Contact us for designs & pricing

BVOC Chamber Set-up - Example

https://doi.org/10.3389/fpls.2021.708711
Example of PTFE Chamber Configuration, Fitzky et al. (2021), FiPS, doi: fpls.2021.708711

Setup of an experiment using the VSI TC-400 VOC chambers, as used by Fitzky et al. (2021), Frontiers in Plant Sciences.  

Ambient air was flushed through a dehumidifier (32% rH) and the charcoal filter (see above for pictures) for providing close-to VOC-free air. The incoming air was entering each TC-400 chamber through an elevated inlet covered by Teflon tape. A mass flow controller was regulating the incoming air pressure. The PTFE-covered table of the TC-400 was dividable, allowing for tree stem insertion, and sealed with a PTFE-coated silicon stopper. A tree was inserted into measurement chambers, whereas a "control" chamber remained empty for parallel VOC background measurements. Up to four chambers were operated in parallel, with one always serving as "blank". A thermocouple (T) was installed at all chambers to monitor leaf / air temperature. A PET-bag was placed over the bottom plate and sealed. Two outlets in the bottom of the PTFE plates of each chamber were used as overflow and for gas analysis by the PTR-TOF-MS and CO2/H2O detector, respectively. See “Materials and Methods” for details, and Supplementary Figure 1 and above for images of the chamber in use.

References Chambers for VOCS, BVOCs
and Ozone Measurements
OPEN

  • Lüpke, M., R. Steinbrecher, M. Leuchner, and A. Menzel. 2017. The Tree Drought Emission MONitor (Tree DEMON), an innovative system for assessing biogenic volatile organic compounds emission from plants. Plant Methods 13:14.
  • Fitzky, A. C., Kaser, L., Peron, A., Karl, T., Graus, M., Tholen, D., ... & Sandén, H. 2023. Same, same, but different: Drought and salinity affect BVOC emission rate and alter blend composition of urban trees. Urban Forestry & Urban Greening, 80, 127842. 
  • Tanaka, P. L., D. T. Allen, and C. B. Mullins. 2003. An environmental chamber investigation of chlorine‐enhanced ozone formation in Houston, Texas. Journal of Geophysical Research: Atmospheres 108.
  • Timkovsky, J., P. Gankema, R. Pierik, and R. Holzinger. 2014. A plant chamber system with downstream reaction chamber to study the effects of pollution on biogenic emissions. Environmental Science: Processes & Impacts 16:2301-2312.
  • Peron, A., et al. 2020. Combined effects of ozone and drought stress on the emission of biogenic volatile organic compounds from Quercus robur L. Biogeosciences, 2020, 1-27. DOI: 10.5194/bg-2020-260
  • Zhang, X., R. Schwantes, R. McVay, H. Lignell, M. Coggon, R. Flagan, and J. Seinfeld. 2015. Vapor wall deposition in Teflon chambers. Atmospheric Chemistry and Physics 15:4197-4214. 

Gas Switching Multiplexing Systems 4 or 8 channels

For switching between PFTE chambers in open flow mode, effective gas multiplexing systems are available. See also Gas Pumps,Gas Flow Monitors, Pressure Sensors and Regulators, ...


Q-S159 CO2 and O2 Analyzer

For parallel measurement of CO2 and O2 in the chambers with a single analyser, consider the Q-S159 CO2 / O2 analyser. Various other Gas Analysing Systems are available.


Sorbent Tube Sampler

Use the AS-101 Sorbent Tube Sampler for volatile (e.g. monoterpenes) sampling for offline analysis.


Gas Flux Measurement Chambers

See ecosystem and mesocosm respiration chambers for plant experiments measuring less reactive gases such as CO2 and O2.



Back to Overview - Air Sampling & Gas Flux Systems
  • Soil Sampling
  • Soil Moisture Monitoring
  • Root and Soil Functioning
  • Root and Soil Observation Systems
  • Germination Paper-Based Phenotyping & Bioassays
  • Root & Rhizobox Imaging
  • Minirhizotron Systems
  • Shoot Phenotyping & Imaging, Photosynthesis
  • Air Sampling & Gas Flux
    • Automatic Air Sampler
    • UAV Air Sampler
    • Vial Evacuator
    • HT Gas Flux Autosampler LAB
    • Teflon / PTFE Chambers
    • Ecosystem Respiration Chambers
    • CO2 Analyzers 2000 ppm
    • High CO2 Analyzers 10%
    • O2 Analyzers
    • O2/CO2 Analyzers
    • Methane CH4 Analyzer
    • Hydrogen H2 Analyzer
    • Gas Multichannel, Monitor, Pump
    • Pressure Sensors Regulators
    • Gas Mixing & Control
    • Dissolved CO2 Analyzer
    • Dissolved O2 Sensor
    • Qubit Interfaces and Software
  • Insect Rearing & Research
  • Animal Behavior & Physiology
  • Laboratory Instruments
  • Open-hardware
  • Teaching Tools for Biology
  • Distributed Products / Retail

Vienna Scientific Instruments GmbH

Heiligenkreuzer Strasse 466, 2534 Alland, AT

office@vienna-scientific.com

+43 650 69 74 672

Contact VSI on WhatsApp

World Class R%D Partners from Austria
About | Terms | Return Policy | Privacy Policy | Cookie Policy | Sitemap
© 2017-2025 Vienna Scientific Instruments GmbH. All rights reserved. Print this page
Log out | Edit
  • Home
  • Engineering
    • Product Development
    • Prototyping
    • Custom-made Spare Parts
    • Field Technical Services
  • Science
    • Research
      • Cross-Sectoral Collaboration
      • BarleyMicroBreed
      • C-SALS
      • HuLK Humus
      • FutureArctic
      • ISO-Drone
      • NextMR-IAA (ATTRACT)
      • PHENET
      • Conferences & Publications
    • Scientific Services
  • Products
    • Soil Sampling
      • Soil Corer
      • Soil Core Storage
      • Soil Ring Sampler
      • Topsoil & Root Corer
      • Soil Water Sampler
      • Root Washer
      • ** Soil Sampling Web Store
    • Soil Moisture Monitoring
      • Drill & Drop Probe
      • EnviroScan Precission
      • Diviner 2000
    • Root and Soil Functioning
      • Soil Respiration
      • Nitrogen Fixation
    • Root and Soil Observation Systems
      • Rhizoboxes
      • RhizonBoxes
      • Hydroponic RootBoxes
      • Racks & Light Shielding
      • Imaging & Manipulation Stands
      • Rhizobox Respiration Chambers
      • Rhizobox Irrigation
      • Rhizotrons & Root Windows
      • * Rhizobox Configuration Form
      • ** Rhizobox Web Store
    • Germination Paper-Based Phenotyping & Bioassays
      • Root Phenoboxes
      • Growth Pouches
      • Germination Pouches
      • Pouch Phenoracks and Stands
      • * Growth Pouch Configuration Form
      • ** Growth Pouch Web Store
    • Root & Rhizobox Imaging
      • Rhizobox Imaging
      • RhizoPot Scanner
      • Benchtop Root Analyzer
      • 2D Root Scanner
      • Root Scanning Trays
      • ** Root Imaging Web Store
    • Minirhizotron Systems
      • Manual MR Systems
      • Semi-Automatic MR Systems
      • Automatic MR Systems
      • Minirhizotron Tubes
      • Coring System for MR Tubes
      • ** Minirhizotron Web Store
    • Shoot Phenotyping & Imaging, Photosynthesis
      • Phenobox
      • Plant Imaging Chamber
      • Chlorophyll Fluorescence
      • Photosynthesis
    • Air Sampling & Gas Flux
      • Automatic Air Sampler
      • UAV Air Sampler
      • Vial Evacuator
      • HT Gas Flux Autosampler LAB
      • Teflon / PTFE Chambers
      • Ecosystem Respiration Chambers
      • CO2 Analyzers 2000 ppm
      • High CO2 Analyzers 10%
      • O2 Analyzers
      • O2/CO2 Analyzers
      • Methane CH4 Analyzer
      • Hydrogen H2 Analyzer
      • Gas Multichannel, Monitor, Pump
      • Pressure Sensors Regulators
      • Gas Mixing & Control
      • Dissolved CO2 Analyzer
      • Dissolved O2 Sensor
      • Qubit Interfaces and Software
    • Insect Rearing & Research
      • Tray and Rack Larval Systems
      • Larvae Mass Rearing Trays
      • Automated Larval Feeding
      • Rearing / Oviposition Cages
      • Oviposition Brushing Machine
      • Insect Sex Separator
      • Insect Collector
      • Release Cages
      • Insect Chill Plates
      • Insect Respirometry
      • Farming Tray Systems
    • Animal Behavior & Physiology
      • Animal Respirometry
      • Aquatic Respirometry
      • Aquatic Control Systems
      • Harness Housings
      • Ports (Photo interrupter Sensors)
      • Operant Boxes
    • Laboratory Instruments
      • Biobase Catalog
      • Labtare Catalog
    • Open-hardware
    • Teaching Tools for Biology
      • Animal and Plant Biology Hands-on
    • Distributed Products / Retail
  • Quote
    • Quote - Soil Corer + Root Washer
    • Quote - Soil Water Sampling
    • Quote - Growth Pouches
    • Quote - Root Shoot Imaging
    • Quote - Minirhizotron
    • Quote - Air Sampling Vial Evac
    • Quote - Gas Analyzers
    • Quote - Insect Rearing and Research
  • Contact
    • Distributors
    • Contact Form
      • Email - Edaphic Scientific (Australia, New Zealand)
      • Email - Eco-Mind (China)
      • Email - DTPLENVIRO (India)
      • Email - Qubit (North America)
    • Partners & Customers
    • Customer Support
      • FAQs
      • Calibration, Maintenance & Repairs
      • Returns
      • Meet Us
    • Social Media
    • Vacancies
    • About VSI
  • Store
  • News
  • Scroll to top